Our Products
Some Of Our Wonderful Products
APC Schneider SRV1KRL UPS
*Key Specifications*
Technology: On-Line Double Conversion.
Power Factor: 0.8.
Power Rating: 1000 VA / 800 Watts.
Input Voltage: 230V Nominal (Accepts wide input voltage range of 110V–285V at half load, and 160V
280V at full load).
Output Waveform: Pure Sine Wave.
Batteries: Internal Sealed Lead-Acid 24V system (Uses replacement cartridge model APCRBCV200).
Recharge Time: Approximately 4 hours to recover 90% capacity.
AC Outlets: 3 × IEC 60320 C13.
Phase: Single Phase Input / Single Phase Output (1:1).
Dimensions (D×W×H): 312 mm × 437 mm × 86 mm (Standard 2U Rackmount Height).
Net Weight: 11 kg.
*Key Features*
Rackmount 2U Form Factor: Tailored specifically to save premium space inside standard server racks, enclosure cabinets, or network closets (Note: standard kit includes rackmount ears but excludes the rail kit; rail kit model SRVRK1 is sold separately).
True Double-Conversion Architecture: Guarantees an instantaneous 0 ms transfer time to battery power during outages, keeping highly sensitive network servers, switches, and storage systems from rebooting.
Intelligent Card Slot (SmartSlot): Equipped with a dedicated expansion port that supports optional network management cards (such as SNMP) for automated remote server shutdowns and web-based monitoring.
High Efficiency ECO Mode: Features an energy-saving utility bypass path that dramatically slashes operational power consumption and system heat generation when grid voltage is running steadily.
Dual Bypass Reliability: Includes both built-in automatic and manual bypass pathways to ensure continuous utility power flows safely down to your network loads even if the UPS faces an internal hardware fault.
Technology: On-Line Double Conversion.
Power Factor: 0.8.
Power Rating: 1000 VA / 800 Watts.
Input Voltage: 230V Nominal (Accepts wide input voltage range of 110V–285V at half load, and 160V
280V at full load).
Output Waveform: Pure Sine Wave.
Batteries: Internal Sealed Lead-Acid 24V system (Uses replacement cartridge model APCRBCV200).
Recharge Time: Approximately 4 hours to recover 90% capacity.
AC Outlets: 3 × IEC 60320 C13.
Phase: Single Phase Input / Single Phase Output (1:1).
Dimensions (D×W×H): 312 mm × 437 mm × 86 mm (Standard 2U Rackmount Height).
Net Weight: 11 kg.
*Key Features*
Rackmount 2U Form Factor: Tailored specifically to save premium space inside standard server racks, enclosure cabinets, or network closets (Note: standard kit includes rackmount ears but excludes the rail kit; rail kit model SRVRK1 is sold separately).
True Double-Conversion Architecture: Guarantees an instantaneous 0 ms transfer time to battery power during outages, keeping highly sensitive network servers, switches, and storage systems from rebooting.
Intelligent Card Slot (SmartSlot): Equipped with a dedicated expansion port that supports optional network management cards (such as SNMP) for automated remote server shutdowns and web-based monitoring.
High Efficiency ECO Mode: Features an energy-saving utility bypass path that dramatically slashes operational power consumption and system heat generation when grid voltage is running steadily.
Dual Bypass Reliability: Includes both built-in automatic and manual bypass pathways to ensure continuous utility power flows safely down to your network loads even if the UPS faces an internal hardware fault.