Our Products
Some Of Our Wonderful Products
APC Schneider SRV2KI UPS
*Key Specifications*
Technology: On-Line Double Conversion.
Power Factor: 0.8.
Power Rating: 2000 VA / 1600 Watts.
Input Voltage: 230V Nominal (Accepts wide input voltage window of 110V–285V at half load, and 160V–280V at full load).
Output Waveform: Pure Sine Wave.
Batteries: Internal Sealed Lead-Acid 48V system (Uses a 48V internal battery bank).
Recharge Time: Approximately 4 hours to recover 90% capacity.
AC Outlets: 4 × IEC 60320 C13.
Phase: Single Phase Input / Single Phase Output (1:1).
Dimensions (D×W×H): 400 mm × 145 mm × 238 mm.
Net Weight: 16.8 kg.
*Key Features*
High-Capacity Tower Design: Provides a localized, space-saving desktop/floor footprint while upgrading output power to handle multiple heavy IT loads or small server clusters.
True Double-Conversion (0 ms Transfer): Continuously converts power from AC to DC and back to AC, guaranteeing zero delay when grid power drops to keep critical servers running flawlessly.
Intelligent Card Slot (SmartSlot): Outfitted with an open expansion port designed for network cards (such as SNMP) to enable remote web management, environment sensing, and automated server safety shutdowns.
High Efficiency ECO Mode: Integrates an advanced energy-saving mode that bypasses internal power components during stable grid periods to minimize building power consumption and operational heat generation.
Internal Automatic & Manual Bypass: Features dual bypass mechanisms to guarantee utility power continues feeding downstream network switches or surveillance hardware even if the UPS meets an internal fault.
Technology: On-Line Double Conversion.
Power Factor: 0.8.
Power Rating: 2000 VA / 1600 Watts.
Input Voltage: 230V Nominal (Accepts wide input voltage window of 110V–285V at half load, and 160V–280V at full load).
Output Waveform: Pure Sine Wave.
Batteries: Internal Sealed Lead-Acid 48V system (Uses a 48V internal battery bank).
Recharge Time: Approximately 4 hours to recover 90% capacity.
AC Outlets: 4 × IEC 60320 C13.
Phase: Single Phase Input / Single Phase Output (1:1).
Dimensions (D×W×H): 400 mm × 145 mm × 238 mm.
Net Weight: 16.8 kg.
*Key Features*
High-Capacity Tower Design: Provides a localized, space-saving desktop/floor footprint while upgrading output power to handle multiple heavy IT loads or small server clusters.
True Double-Conversion (0 ms Transfer): Continuously converts power from AC to DC and back to AC, guaranteeing zero delay when grid power drops to keep critical servers running flawlessly.
Intelligent Card Slot (SmartSlot): Outfitted with an open expansion port designed for network cards (such as SNMP) to enable remote web management, environment sensing, and automated server safety shutdowns.
High Efficiency ECO Mode: Integrates an advanced energy-saving mode that bypasses internal power components during stable grid periods to minimize building power consumption and operational heat generation.
Internal Automatic & Manual Bypass: Features dual bypass mechanisms to guarantee utility power continues feeding downstream network switches or surveillance hardware even if the UPS meets an internal fault.